{"product_id":"viking-enterprise-solutions-vds41022-102-bay-3-5-sas-24gb-s-4u-rackmount-dual-ioms-storage-expansion-enclosure-jbod-no-drives-new","title":"Viking Enterprise Solutions VDS41022 102-Bay 3.5\" SAS 24Gb\/s 4U Rackmount Dual IOMs Storage Expansion Enclosure JBOD No Drives (New)","description":"\u003c!-- more --\u003e\n\u003cdiv\u003e\n\u003ch3 dir=\"ltr\"\u003eViking Enterprise Solutions VDS41022 JBOD Storage Enclosure\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThe Viking Enterprise Solutions VDS41022 is a high-density enterprise SAS-4 JBOD expansion enclosure built for large-scale storage capacity growth in data center and archival environments. Unlike iSCSI or controller-based storage arrays, the VDS41022 works as a direct-attached SAS expansion shelf. It relies on external servers or RAID\/HBA controllers for storage management and has no onboard RAID. It connects to a host system with a SAS HBA or RAID controller through SFF-8674 mini-SAS HD cabling, and can be daisy-chained with additional enclosures for further expansion. This unit is sold as an enclosure only. No drives are included.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra-Dense 4U Chassis:\u003c\/strong\u003e Houses 102 hot-pluggable 3.5-inch drive slots in a 4U rackmount form factor. It fits an industry-standard 19-inch wide, 1.0-meter deep rack and measures 6.9 in. H x 17.2 in. W x 39.4 in. D.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24Gb\/s SAS-4 Expansion Architecture:\u003c\/strong\u003e Equipped with dual SAS-4 I\/O modules (IOMs), each providing four 4-wide SFF-8674 24Gb\/s mini-SAS HD expansion ports. The dual IOMs provide true failover, so the system stays fully operational on a single I\/O module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrive Compatibility Flexibility:\u003c\/strong\u003e 12Gb\/s SAS is supported on all 102 drive slots, which accept LFF or SFF drives. In the single I\/O module configuration, the enclosure supports 12Gb\/s and 6Gb\/s SAS drives as well as 6Gb\/s SATA drives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier-Grade Redundancy:\u003c\/strong\u003e Features hot-pluggable drives, I\/O controllers and fan modules. It has redundant, high-efficiency 1600W power supplies (n+1) with two independent AC power inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Enclosure Management:\u003c\/strong\u003e Supports in-band SCSI Enclosure Services (SES-3.0) with system status and FRU LEDs. It monitors temperature, power, cooling (including fan speed control), disk drives and I\/O modules, and reports all FRU and chassis serial numbers, part numbers and revisions in-band.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e Requires 200–240V AC, 50–60Hz input, with up to 9.4A per power supply at 200V AC. This enclosure is not designed to run on a standard 120V North American outlet.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Ships with a standard rackmount rail kit and cable management arm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnterprise Data Centers:\u003c\/strong\u003e High-density SAS storage expansion for server environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup \u0026amp; Archival:\u003c\/strong\u003e Reliable long-term storage for backups and data retention\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVirtualization Platforms:\u003c\/strong\u003e Virtual machine storage pools and hypervisor datastores\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBig Data \u0026amp; Analytics:\u003c\/strong\u003e Scalable storage for large datasets and processing workloads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedia \u0026amp; Surveillance Storage:\u003c\/strong\u003e High-capacity storage for video production and security systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cse-table\"\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Many configurations available, contact us via \u003ca href=\"mailto:Sales@ServerPartDeals.com\" title=\"email\"\u003eemail\u003c\/a\u003e or \u003ca href=\"tel:866-331-3021\" title=\"call us\"\u003ecall us\u003c\/a\u003e for custom options\u003c\/p\u003e\n\u003cstrong\u003eDatasheet: \u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0011\/8675\/8756\/files\/Viking_VDS41022_Product_Brief_datasheet.pdf?v=1793035522\" rel=\"noopener\" target=\"_blank\"\u003eViking VDS41022 Product Brief\u003c\/a\u003e\u003cbr\u003e\n\u003cdiv class=\"cse-table\"\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eS\u003c\/strong\u003e\u003cstrong\u003epecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100% !important\" style=\"height: 777.773px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5909px;\"\u003e\n\u003ctd style=\"height: 35.5909px; width: 27.2563%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5909px; width: 72.3827%;\"\u003e\n\u003cp\u003eViking Enterprise Solutions\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5909px;\"\u003e\n\u003ctd style=\"height: 35.5909px; width: 27.2563%;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5909px; width: 72.3827%;\"\u003e\n\u003cp\u003eHigh Density JBOD\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5909px;\"\u003e\n\u003ctd style=\"height: 35.5909px; width: 27.2563%;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5909px; width: 72.3827%;\"\u003e\n\u003cp\u003eVDS41022\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5909px;\"\u003e\n\u003ctd style=\"height: 35.5909px; width: 27.2563%;\"\u003e\u003cstrong\u003e\u003cspan class=\"Yjhzub\"\u003eForm Factor\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5909px; width: 72.3827%;\"\u003e\n\u003cp\u003e\u003cspan\u003e4U Rackmount JBOD Expansion Enclosure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1818px;\"\u003e\n\u003ctd style=\"width: 27.2563%; height: 55.1818px;\"\u003e\u003cstrong\u003e\u003cspan class=\"Yjhzub\"\u003eDrive Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3827%; height: 55.1818px;\"\u003e\n\u003cp\u003e\u003cspan\u003e102× hot-pluggable 3.5\" drive slots (LFF or SFF compatible) (No Drives Included)\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5909px;\"\u003e\n\u003ctd style=\"width: 27.2563%; height: 35.5909px;\"\u003e\u003cstrong\u003e\u003cspan class=\"Yjhzub\"\u003eDrive Interface\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3827%; height: 35.5909px;\"\u003e\n\u003cp\u003e\u003cspan\u003e12Gb\/s SAS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1818px;\"\u003e\n\u003ctd style=\"width: 27.2563%; height: 55.1818px;\"\u003e\u003cstrong\u003e\u003cspan class=\"Yjhzub\"\u003eCompatible Base Arrays \u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3827%; height: 55.1818px;\"\u003e\n\u003cp\u003e\u003cspan\u003eNot required — connects to any host with a standard SAS HBA or RAID controller\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5909px;\"\u003e\n\u003ctd style=\"width: 27.2563%; height: 35.5909px;\"\u003e\u003cstrong\u003e\u003cspan class=\"Yjhzub\"\u003eExpander\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3827%; height: 35.5909px;\"\u003e\n\u003cp\u003e\u003cspan\u003eJBOD (Dual SAS-4 I\/O Modules, no onboard RAID controllers)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1818px;\"\u003e\n\u003ctd style=\"height: 55.1818px; width: 27.2563%;\"\u003e\u003cstrong\u003e\u003cspan class=\"Yjhzub\"\u003eHost\/Expansion\u003cbr\u003eInterface\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1818px; width: 72.3827%;\"\u003e\n\u003cp\u003e\u003cspan\u003eDual SAS-4 I\/O Modules (IOMs), four 4-wide 24Gb\/s SFF-8674 mini-SAS HD ports per IOM, via external SAS HBA or RAID controller\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5909px;\"\u003e\n\u003ctd style=\"height: 35.5909px; width: 27.2563%;\"\u003e\u003cstrong\u003e\u003cspan class=\"Yjhzub\"\u003eCooling\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5909px; width: 72.3827%;\"\u003e\n\u003cp\u003e\u003cspan\u003eHot-pluggable fan modules with fan speed control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5909px;\"\u003e\n\u003ctd style=\"height: 35.5909px; width: 27.2563%;\"\u003e\u003cstrong\u003e\u003cspan class=\"Yjhzub\"\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5909px; width: 72.3827%;\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003eRedundant dual 1600W hot-pluggable power supplies (n+1)\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5909px;\"\u003e\n\u003ctd style=\"width: 27.2563%; height: 35.5909px;\"\u003e\u003cstrong\u003e\u003cspan class=\"Yjhzub\"\u003eA\/C Input\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3827%; height: 35.5909px;\"\u003e\n\u003cp\u003e\u003cspan\u003e200–240V AC, 50\/60Hz (enterprise high-line power)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 74.7727px;\"\u003e\n\u003ctd style=\"width: 27.2563%; height: 74.7727px;\"\u003e\u003cstrong\u003e\u003cspan class=\"Yjhzub\"\u003eOperating\u003cbr\u003eEnvironment\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3827%; height: 74.7727px;\"\u003e\n\u003cp\u003e\u003cspan\u003eTemperature: 41 – 95°F (5 – 35°C)\u003cbr\u003eHumidity (non-condensing): 20% to 80% RH\u003cbr\u003eAltitude: -200 ft to 10,000 ft\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 74.7727px;\"\u003e\n\u003ctd style=\"width: 27.2563%; height: 74.7727px;\"\u003e\u003cstrong\u003e\u003cspan class=\"Yjhzub\"\u003eNon-operating\u003cbr\u003eEnvironment\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3827%; height: 74.7727px;\"\u003e\n\u003cp\u003e\u003cspan\u003eTemperature: 41 – 113°F (5 – 45°C)\u003cbr\u003eHumidity (non-condensing): 10% to 90% RH\u003cbr\u003eAltitude: -200 ft to 10,000 ft\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5909px;\"\u003e\n\u003ctd style=\"width: 27.2563%; height: 35.5909px;\"\u003e\u003cstrong\u003e\u003cspan class=\"Yjhzub\"\u003eExpansion Height\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3827%; height: 35.5909px;\"\u003e\n\u003cp\u003e\u003cspan\u003e17.20 cm (6.90 in)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5909px;\"\u003e\n\u003ctd style=\"width: 27.2563%; height: 35.5909px;\"\u003e\u003cstrong\u003e\u003cspan class=\"Yjhzub\"\u003eExpansion Width\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3827%; height: 35.5909px;\"\u003e\n\u003cp\u003e\u003cspan\u003e43.80 cm (17.20 in)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5909px;\"\u003e\n\u003ctd style=\"width: 27.2563%; height: 35.5909px;\"\u003e\u003cstrong\u003e\u003cspan class=\"Yjhzub\"\u003eExpansion Depth\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3827%; height: 35.5909px;\"\u003e\n\u003cp\u003e\u003cspan\u003e100.00 cm (39.40 in)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Viking Enterprise Solutions","offers":[{"title":"Default Title","offer_id":67820969001238,"sku":"VDS41022-CS_NB","price":4499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/8675\/8756\/files\/DSC05364.png?v=1793274520","url":"https:\/\/serverpartdeals.com\/products\/viking-enterprise-solutions-vds41022-102-bay-3-5-sas-24gb-s-4u-rackmount-dual-ioms-storage-expansion-enclosure-jbod-no-drives-new","provider":"ServerPartDeals.com","version":"1.0","type":"link"}